Documentation

Technical data

Specifications, variants and scope of delivery of the Smart Meter Adapter.

Variants

Which variant you need depends solely on the meter. The meter finder makes the decision for you.

Variant Part number Supported interfaces Editions
SMA MBUS variant SMA-MBUS M-Bus, Wireless M-Bus Secured, Open CPU
SMA UART variant SMA-UART DSMR (P1), Infrared (IEC 62056-21), HAN Secured, Open CPU
IR reading head (IEC 62056-21) SMA-IRH Infrared (IEC 62056-21) Accessory

Specifications

Power supply
USB-C, or from the meter where it feeds the interface
Power consumption
typ. 1 W, depending on WiFi signal strength
Protection class
IP20 — indoor use only
Ambient temperature
−25 °C to +75 °C
Humidity
≤ 95 % relative humidity, non-condensing
Adapter dimensions
18 × 45 × 52.8 mm (W × D × H); 55.6 mm with the DIN rail clip, 67.9 mm including the angled antenna connector
Width
18 mm — 1 module unit of a standard DIN rail
IR reading head dimensions
Ø 32 mm, 24 mm deep; magnetic mount to IEC 62056-21
Mounting
DIN rail, wall mounting or adhesive mounting; IR reading head magnetically on the meter
WiFi operating mode
Access point and infrastructure
WiFi encryption
IEEE 802.11 open, WEP, WPA, WPA2
Antenna
Detachable WiFi antenna with SMA connector; internal antenna for Wireless M-Bus
Meter interfaces
M-Bus, Wireless M-Bus, DSMR (P1), infrared to IEC 62056-21
Optical interface
IEC 62056-21 IR reading head, magnetic, connected over RJ12 to the UART variant
Data interfaces
Web dashboard (HTTPS/HTTP), JSON REST API, MQTT client, Modbus TCP
Concurrent connections
maximum 3
Connection cables
RJ12 and RJ45 included; third-party cables must have mirrored pinout, max. 3 m
Decryption
On the device, using the meter key from the grid operator
Data storage
No consumption values are stored on the device

Figures as per the datasheet. Which readings are actually available depends on the meter type and the grid operator.

Dimensioned drawings

All measurements in millimetres. The adapter is 18 mm wide and therefore occupies one module unit on the DIN rail; the IR reading head follows IEC 62056-21.

Dimensioned drawing of the Smart Meter Adapter, measurements in millimetres
Smart Meter Adapter: front, side and DIN rail views with dimensions.
Dimensioned drawing of the IEC 62056-21 IR reading head, measurements in millimetres
IEC 62056-21 IR reading head: Ø 32 mm, 24 mm deep, magnetic mount.

Status LED

The LED on the front shows the operating state at a glance.

Colour State Meaning
Steady The device is booting. This can take up to 30 seconds.
Steady Connected to WiFi, the device is ready.
Steady Access point active — a direct connection to the device is possible.
Steady Error receiving meter data, or a WiFi connection problem.
2 seconds The device is being reset to factory settings.
Blinking A data packet was received from the meter; the LED then returns to its previous state. With Wireless M-Bus the LED does not blink but stays steady green.
Steady The device is in recovery mode.

Button

A single button covers both access and factory reset.

Duration Meaning
up to 3 seconds Activates the access point — direct access from a phone or laptop becomes possible.
10 seconds or more Factory reset. All meter data and settings are erased.

What’s in the box

Adapter

  • Smart Meter Adapter in the chosen variant
  • RJ12 and RJ45 connection cables
  • USB-C cable for power
  • Detachable WiFi antenna (SMA connector)
  • DIN rail clip
  • Double-sided adhesive pad

IR reading head (IEC 62056-21)

  • IEC 62056-21 IR reading head with magnetic mount
  • RJ12 connection cable

RJ12 and RJ45 are both included — you do not have to choose a connector type when ordering.

Exploded view: enclosure, main board with ESP32-S2, interface board, front panel and antenna socket
Construction: enclosure, main board with ESP32-S2, plug-on interface board, front panel with antenna socket and rating label.